Skip to content

Hall equipment — Paloma POS 2 ​

This article is about Paloma POS 2. The «Hall equipment» section controls the light over tables together with the tariff (billiards, cabins) and can open a turnstile — through an equipment driver on a PC in the hall. If you are not sure which product you have, start with «How to tell you have Paloma POS 2».

Also called: billiard table lights, automatic light by tariff, light relay.

Overview ​

  • Light by tariff: it switches on when the tariff starts and off on a pause or stop. With prepaid time — when the time is up.
  • A turnstile can be opened through the same driver instead of the register's USB relay — see «Turnstile and entry tickets».
  • The driver is a separate program on a PC in the hall that the relays are connected to. The register makes every decision.
  • The chosen driver and the bindings are shared by the registers of the point. The key is entered on each register separately.

Setup ​

  1. Open «Settings» → «Hardware» → «Hall equipment».
  2. «Driver» → «Find on the network» → choose it in «Drivers found». The register and the driver PC must be on the same network.
  3. «This till's key» → «Enter key»: the key is shown on the driver's setup screen. Repeat on each register.
  4. «Channels»: for each channel choose the table it lights. A channel is tested right here: the light goes on and off, the turnstile — with «Pulse».
  5. «Turnstile»: choose «Entry channel» and «Exit channel» if the driver opens the turnstile.
  6. «Light check»: turn on «Check the light from this till» on one register of the point. Every 45 seconds it checks that only occupied tables are lit.

Common problems ​

  • «No driver found. Check that the driver PC is on and connected to the same network as this till.» — turn the PC on, check the network and repeat «Find on the network».
  • «The driver did not accept the key.» — enter the key again: «Replace key».
  • «No key entered — this till does not control the equipment» — enter the key on this register.
  • «Relay offline» or «The relay does not respond.» — check the relay's power and connection.
  • «Channel is off in the driver» — turn the channel on in the driver program.
  • The light is on over a free table — check that at least one register does the light check («No till checks the light now» — turn it on).

FAQ ​

No «Hall equipment» section ​

It is not supported on this device. Open the settings on another register of the point.

Does the light go off when a guest paid for time in advance? ​

Yes, when the prepaid time is up. With open time the light stays on until the tariff is stopped.